104349_p.eps
PVC Network cables · ETHERNET · shielded

LÜTZE ELECTRONIC ETHERNET (C) PVC

Logo

Logo

Identification

Type

EL ET (C) PVC (2×2×AWG22/7)StC Cat5e

Part No.

104197

Product status

Series

Use/Application/Properties

Application

  • For wiring of industrial field bus systems with the globally accepted TCP/IP protocol
  • For fixed installation or moving use without compulsory guide in the automation technology, transport and conveyor technology, machine tool manufacture
  • Cable design for harsh industrial environments and operating conditions with high noise levels
  • Application in automation technology, transport and conveyor technology, machine tool manufacture
  • Compliant with NFPA 79 requirements

Properties

  • High protection against electromagnetic interferences (EMI)
  • Talc free and silicone free
  • RoHS compliant
  • Specially formulated jacket for oil resistance

Technical Data

Construction

Ethernet Key

SF/UTP

Description

ELECTRONIC ETHERNET (C) PVC

Number of conductors/cross-section

(2×2×AWG22/7)

Number of conductors

4

Cross-section AWG

AWG 22

Jacket material

PVC

Jacket color

teal similar to RAL 5018

Outer Ø

7.5 mm

Outer Ø

0.295 inch

Surface

adhesion-free

Weight

6.4 kg/100 m

Weight

43 Lbs/Mft

Cu Index

2.97 kg/100 m

Cu Index

20 Lbs/Mft

Element 1

Element construction

(2×2×AWG22/7)

Conductor construction

AWG 22/7

Conductor

  • AWG conductor
  • CU-wire tin-plated

Conductor marking standard

ISO IEC 11801

Conductor insulation

Special Polyolefin

Cabling

Conductors twisted in pairs

overall construction

Overall shield

  • Aluminium-laminated film shield
  • Braid shield
  • Tinned copper wires
  • Optical cover approx. 85 %

Jacket characteristics

  • Flame-retardant
  • Oil resistant
  • Silicone free

Technical data

Rated voltage

300 V

Rated voltage UN

  • 600 V AWM 2570
  • 300 V PLTC

Test voltage type

AC 1500 V

Temperature according to UL

80 °C

Temperature range moving

-5 °C … +70 °C

Temperature range fixed

-30 °C … +80 °C

Minimum bending radius moving

12×cable OD

Minimum bending radius fixed

6×cable OD

Element 1

Element construction

(2×2×AWG22/7)

Insulation resistance at 20 °C

≥ 5.000 MΩ×km

Operating capacitance wire-wire

ca. 50 pF/m

Loop resistance

≤ 114.8 mΩ/m

Impedance

nom. 100 Ω

Approvals/Standards

Approvals

  • cULus
  • CMR
  • CMX Outdoor
  • PLTC
  • cURus
  • Class I and II, Div. 2
  • Class 1 Div. 2 per NEC
  • 501, 502, 505

UL style

AWM 2570

Conformity

  • CE
  • RoHS
  • REACH
  • TSCA

Burning behavior according to

  • DIN EN 60332-1-2
  • DIN EN 60332-3-24
  • UL 1685
  • UL FT4

Oil resistant according to

Oil Res I

General

Note

CE These products are in conformity with the EU Low Voltage Directive 2014/35/EU

Downloads

Data sheet Item-No. 104197

Download, PDF, n.A.
104197_DS_EN_V06.pdf

Data sheet Item-No. 104197

Download, PDF, n.A.
104197_DS_US_V06.pdf

Price of Copper Item-No. 104197

Download, PDF, n.A.
Kupferpreis_EN.pdf

Chemical resistance Item-No. 104197

Download, PDF, n.A.
chemische Bestaendigkeit_EN.pdf

Bitte überprüfen Sie Ihre Länder- bzw. Spracheinstellung

Ihre aktuellen Einstellungen unterscheiden sich von denen der angeforderten Seite.

Möchten Sie zu der vorgeschlagenen Länder- bzw. Spracheinstellung wechseln?

Zu Deutschland / Deutsch wechseln Ein anderes Land / Sprache wählen

Please check your country or language setting

Your current settings are different from those of the requested page.

Would you like to change to the suggested country or language setting?

Change to International English Choose other country / language

Please check your country or language setting

Your current settings are different from those of the requested page.

Would you like to change to the suggested country or language setting?

Change to American English Choose other country / language

Überprüfen Sie Ihre Regionseinstellungen

Ihre aktuellen Einstellungen unterscheiden sich von denen der angeforderten Seite.

Möchten Sie zu der vorgeschlagenen Länder- bzw. Spracheinstellung wechseln?

Zu Österreich / Deutsch wechseln Ein anderes Land / Sprache wählen

Bitte überprüfen Sie Ihre Länder- bzw. Spracheinstellung

Ihre aktuellen Einstellungen unterscheiden sich von denen der angeforderten Seite.

Möchten Sie zu der vorgeschlagenen Länder- bzw. Spracheinstellung wechseln?

Zu Schweiz / Deutsch wechseln Ein anderes Land / Sprache wählen

Please check your country or language setting

Your current settings are different from those of the requested page.

Would you like to change to the suggested country or language setting?

Change to British English Choose other country / language

Veuillez vérifier vos réglages de pays ou de langue

Vos réglages actuels sont différents de ceux de la page requise.

Voulez-vous appliquer le réglage de pays ou de langue suggéré?

Passer au réglage La France/Français Choisir un autre pays / une autre langue

Veuillez vérifier vos réglages de pays ou de langue

Vos réglages actuels sont différents de ceux de la page requise.

Voulez-vous appliquer le réglage de pays ou de langue suggéré?

Passer au réglage Suisse/Français Choisir un autre pays / une autre langue

Compruebe su configuración de país y de idioma

Su configuración actual se diferencia de la de la página solicitada.

¿Desea cambiar a la configuración de país o idioma propuesta?

Cambiar a España / Español Seleccionar otro país / idioma

中國