LOCC-Box - Electronic Circuit Breakers
When factory uptime is important, then let the electronic circuit breaker (ECB) LOCC-Box monitor and protect the control circuits to minimize manufacturing downtime and keep the equipment running. With the real time output status indicators, you are able to remotely and proactively monitor devices to ensure reliable operation on the plant floor. By implementing the LOCC-Box, you can reduce your service and maintenance costs - and at the same time increase operational reliability and plant safety.
LUTZE's electronic circuit breaker LOCC-Box provides reliable load monitoring and protection in 24V DC control circuits. Innovative features include adjustable trip current range (1-10A), patented adjustable characteristics (fast, med, slow 1, slow 2 and slow 3), output alarm signal at 90% of the load setting, remote reset and remote on/off functions. In addition to factory floor applications, LOCC-Box serves very well in remote locations and other hard to access applications. Narrow construction ensures compact design even with multi-channel configurations. No derating required as electronic circuit breaker LOCC-Box functions independently of ambient temperature.
Additional features such as Gateway communication capabilities for remote monitoring and analysis are possible with the LUTZE LOCC-Box Net. Optional LOCC-Pads software offers the possibility for custom parameter setting, analysis and diagnostics. These are just some of the intelligent features of LUTZE's electonic circuit breaker LOCC-Box.
We invite you to learn more:
- 24V DC control voltage protection
- Adjustable current range (1-10A)
- Patented adjustable characteristics: fast, medium, slow 1, slow 2, slow 3
- Output alarm signal at 90% of the load setting
- Output trip alarm
- LED status indicator on/off/alarm
- Remote reset
- Remote on/off
- Ideal for remote locations
- Independent of ambient temperature, no derating required
- Single and multi-channel options
- Narrow housing, only 8.1 mm in width
- DIN rail mountable
- Gateway communication via Ethernet/IP, Profinet IO, Profibus DP, EtherCAT, CANopen or RS232 for remote monitoring (optional)
- Input supply terminal with busbar capabilities (optional)
LCOS CC Control Circuit Protection
The LCOS CC system belongs to LUTZE's electronic circuit breaker devices and is part of the LCOS modular housing system.
Available in 1 or 2 channel design with a powerbus for the return circuit. The load can be connected directly to the device and diagnostics are possible via LOCC-Pads or the fieldbus.
Further products